Special Tools
For equivalent regional tools, refer to Special Tools.
WARNING: In order to reduce the risk of personal injury, loss of high voltage isolation to ground and higher system impedance, do not attempt to repair any HV wiring, connector, or terminal that is damaged. High voltage coaxial type cables are not repairable. Never attempt to repair a coaxial type cable. The entire cable/harness or component must be replaced. In order to maintain system integrity and personal safety, never attempt to repair any high voltage wiring, cables, or terminals. Performing this procedure on high voltage circuits may result in serious injury or death.
CAUTION: If the SIR/SRS wiring, connector, or terminal is damaged, the affected wiring harness must be replaced. Do not attempt to repair the wiring, connector, or terminals. Any attempt to repair the wires, connectors, or terminals could result in performance problems of the SIR/SRS System.
Operations on restraint systems must only be performed by trained and qualified personnel.
NOTE: If the wiring harness internal to the transmission is damaged, the wiring harness must be replaced. The use of splice sleeves in an attempt to repair the internal transmission wires, connectors, or terminals could result in performance issues.
NOTE: Do not splice wires in Door Harness Grommets.
NOTE: Use only DuraSeal splice sleeves. Other splice sleeves may not protect the splice from moisture or provide a good electrical connection.
Use DuraSeal splice sleeves to form a one-to-one splice on all types of insulation except Tefzel and coaxial. Use DuraSeal splice sleeves where there are special requirements such as moisture sealing.
Follow the instructions below in order to splice copper wire using DuraSeal splice sleeves.
NOTE: Perform the following procedures in the listed order. Repeat the procedure if any wire strands are damaged. Obtain a clean strip with all of the wire strands intact.
1. Open the harness by removing any tape:
2. Cut as little wire off the harness as possible. Extra wire length may be needed in order to change the location of a splice.
Adjust splice locations so that each splice is at least 40 mm (1.5 in) away from the other splices, harness branches, or connectors.
3. Strip the insulation:
4. For high temperature wiring, slide a section of high temperature SCT1 shrink tubing down the length of wire to be spliced. Ensure that the shrink tubing will not interfere with the splice procedure.
5. Select the proper DuraSeal splice sleeve according to the wire size. Refer to the above table at the beginning of the repair procedure for the color coding of the DuraSeal splice sleeves and the crimp tool nests.
6.
The EL-38125-10 splice sleeve crimping tool has four crimp nests. The largest crimp nest (4) is used for crimping 10 and 12 gauge wires. The second largest crimp nest (3) is used for crimping 14 and 16 gauge wires. The third largest crimp nest (2) is used for crimping 18 and 20 gauge wires. The smallest crimp nest (1) is used for crimping 22 to 26 gauge wires. The crimp nests are referenced in the table (farther above) under the crimp tool nest color.
7.
The J-38125-8 splice sleeve crimping tool has three crimp nests. The largest crimp nest (3) is used for crimping 10 and 12 gauge wires. The second largest crimp nest (2) is used for crimping 14 and 16 gauge wires. The smallest crimp nest (1) is used for crimping 18 to 20 gauge wires. The crimp nests are referenced in the table (farther above) under the crimp tool nest color.
8. Use the splice sleeve crimp tool in order to position the DuraSeal splice sleeve in the proper color nest of the splice sleeve crimp tool. For the four crimp nest tool, use the three largest crimp nests to crimp the splice sleeves. For the three crimp nest tool, use all three crimp nests to crimp the splice sleeves. Use the four and three crimp tool diagrams (above) and the table (farther above) to match the splice sleeve with the correct crimp nest. The crimp tool diagram callout numbers match the numbers in the table (under crimp tool nest color).
9.
Place the DuraSeal splice sleeve in the nest. Ensure that the crimp falls midway between the end of the barrel and the stop. The sleeve has a stop (3) in the middle of the barrel (2) in order to prevent the wire (1) from going further. Close the hand crimper handles slightly in order to firmly hold the DuraSeal splice sleeve in the proper nest.
10.
Insert the wire into the splice sleeve barrel until the wire hits the barrel stop.
11. Tightly close the handles of the crimp tool until the crimper handles open when released.
The crimper handles will not open until the proper amount of pressure is applied to the DuraSeal splice sleeve. Repeat steps 4 and 6 for the opposite end of the splice.
12.
Using the heat torch, apply heat to the crimped area of the barrel.
13. Start in the middle and gradually move the heat barrel to the open ends of the tubing:
High Temperature Wiring Repairs
Use the following procedures to perform high temperature wiring repairs:
1. Center the high temperature SCT1 shrink tube over the DuraSeal splice sleeve.
2. Using the heat torch, apply heat to the high temperature heat shrink tubing.
3. Gradually move the heat from the center to the open end of the tubing:
4. Replace any reflective tape and clips that may have been removed during the repair.